International Journal of Technology and Applied Science
E-ISSN: 2230-9004
•
Impact Factor: 9.914
A Widely Indexed Open Access Peer Reviewed Multidisciplinary Bi-monthly Scholarly International Journal
Plagiarism is checked by the leading plagiarism checker
Call for Paper
Volume 17 Issue 11
November 2026
Indexing Partners
Beyond Periodic Calibration: An Uncertainty-Aware Artificial Intelligence Framework for Predictive Instrument Drift Monitoring, Measurement Reliability, and Risk-Based Calibration Optimization
| Author(s) | Himabindhu Kondeti, Onuh Matthew Ijiga, Bhavesh Kataria |
|---|---|
| Country | United States |
| Abstract | Periodic calibration can leave progressive instrument drift undetected between scheduled verifications, with consequences for measurement reliability and industrial quality assurance. This paper develops an uncertainty-aware artificial intelligence framework centred on the Smart Instrument Calibration Monitoring Device (UK registered design No. 6564151), integrating multichannel calibration correction, time-dependent drift prediction, measurement uncertainty, conformity decisions, and adaptive calibration scheduling. The supplied numerical case study covers an eleven-point pressure calibration series, a 180-day drift profile, thermal-response scenarios, and comparisons of the proposed UAC-PROA approach with XGBoost, LSTM, random forest, and support vector regression. In those data, UAC-PROA has a reported root mean square error of 0.0068 bar, mean absolute error of 0.0049 bar, and coefficient of determination of 0.965. At the 5-bar reference condition, the combined standard and expanded uncertainties are 0.00735 and 0.01470 bar, respectively. For a 30-instrument fleet, the scheduling scenario specifies 65 annual calibrations under UAC-PROA compared with 120 under a fixed 90-day policy. The integrated analysis illustrates how predictive accuracy, metrological uncertainty, and risk-constrained scheduling can be assessed in one decision framework, while physical prototype validation and independent longitudinal data remain necessary for performance claims. |
| Keywords | instrument calibration, machine learning, measurement uncertainty, predictive drift, risk-based maintenance, smart metrology, UAC-PROA. |
| Published In | Volume 17, Issue 11, November 2026 |
| Published On | 2026-11-27 |
Share this

Crossref DOI prefix of IJTAS is 10.71097/IJTAS
Downloads
All research papers published on this website are licensed under Creative Commons Attribution-ShareAlike 4.0 International License, and all rights belong to their respective authors/researchers.