A comparison of rapid screening test and ELISA for the diagnosis of Hepatitis B in a tertiary care hospital in Central India

Author(s) Dr. Nishu Sharma, Dr. Neha Sharma, Dr. Priyanka Kalbhor, Dr. Vaishali Rahangdale, Dr. Sunanda Shrikhande
Country India
Abstract Background: Hepatitis B virus (HBV) is often transmitted silently, so accurate detection of HBsAg is essential. Rapid immunochromatographic tests (ICT) are cheap and need little technical expertise. ELISA is more costly and is mostly used in better-equipped laboratories.

Objective: To compare a rapid ICT card test with ELISA for detecting HBsAg in a tertiary care hospital in Central India.

Methods: This cross-sectional study ran from January to March 2024 at the Department of Microbiology, Government Medical College, Nagpur. It included 5,439 serum samples sent for HBsAg testing from various hospital departments. Stored (>3 days), contaminated and heat-inactivated samples were excluded, as were samples preserved with sodium azide. Every sample was tested by both the Mediline-SA HBsAg Combo Rapid Test and the Trustwell HBsAg ELISA kit. With ELISA as the reference standard, sensitivity, specificity, positive and negative predictive values (PPV, NPV) and diagnostic accuracy were calculated.

Results: The rapid test was positive in 112 samples and negative in 5,327. ELISA was positive in 105 and negative in 5,334. Of the 105 ELISA-positive samples, the rapid test detected 104. It gave 8 false positives and 1 false negative. Compared with ELISA, the rapid test had:

sensitivity of 99.04%
specificity of 99.85%
PPV of 92.85%
NPV of 99.98%
diagnostic accuracy of 99.83%

Conclusion: The rapid ICT performed well, but ELISA was more sensitive, since the rapid test missed one true positive. Rapid tests can serve for screening where resources are limited, such as remote areas and peripheral health centres. The authors recommend ELISA for diagnosing HBV wherever it is available, to avoid missed infections and silent transmission.
Keywords Keywords: Hepatitis B, HBsAg, rapid card test, ICT, ELISA, diagnostic accuracy